Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column identifies nine impurities in potable ethanol in 30 minutes.
- Publication Part Number: A01320
- Created: 30 Nov 2015
- 871 KB
Publication Part Number | A01320 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
7820GC and 7697A HSS for residual solvents analysis in packaging material
- Publication Part Number: 5991-2044EN
- Created: 21 Mar 2013
- 667 KB
Publication Part Number | 5991-2044EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates ten common residual solvents in four minutes.
- Publication Part Number: A01457
- Created: 31 Oct 2011
- 452 KB
Publication Part Number | A01457 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a 0.15 mm id Agilent J&W CP-Sil 5 CB column reduces run time in the separation of residual solvents from 25 minutes to less than seven minutes.
- Publication Part Number: A01501
- Created: 31 Oct 2011
- 660 KB
Publication Part Number | A01501 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with headspace analysis and an Agilent J&W CP-Select 624 CB column separates 18 solvent standards in DMSO in 30 minutes.
- Publication Part Number: A01389
- Created: 31 Oct 2011
- 573 KB
Publication Part Number | A01389 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates 26 solvents in DMSO in 27 minutes.
- Publication Part Number: A01424
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01424 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-1301 column separates 26 residual solvents in 49 minutes.
- Publication Part Number: A01266
- Created: 31 Oct 2011
- 808 KB
Publication Part Number | A01266 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select 624 CB column separates seven residual solvents in a drug in ten minutes.
- Publication Part Number: A01302
- Created: 31 Oct 2011
- 594 KB
Publication Part Number | A01302 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates 32 solvents in 44 minutes, according to USP 467.
- Publication Part Number: A01546
- Created: 31 Oct 2011
- 892 KB
Publication Part Number | A01546 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a 0.15 mm id Agilent J&W CP-Sil 5 CB column separates residual solvents in less than seven minutes.
- Publication Part Number: A01502
- Created: 31 Oct 2011
- 788 KB
Publication Part Number | A01502 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Graphical analysis ot residual solvents of USP 467.
- Publication Part Number: SI-00944
- Created: 08 Oct 2010
- 216 KB
Publication Part Number | SI-00944 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机For USP-467 with Agilent J&W VF-624ms, replacing a 30 m x 0.32 mm column for one of 15 m x 0.15 mm reduces analysis time by more than half.because the efficiency is higher.
- Publication Part Number: A02430
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02430 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Separation of trace impurities in ethanol in a pharmaceutical application uses gas chromatography with an Agilent J&W VF-1701ms column.
- Publication Part Number: A02409
- Created: 11 May 2010
- 834 KB
Publication Part Number | A02409 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W VF-624ms GC column resolves residual solvents in 12 minutes.
- Publication Part Number: A02433
- Created: 11 May 2010
- 759 KB
Publication Part Number | A02433 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Separation of six trace impurities in ethanol by gas chromatography with an Agilent J&W VF-1701ms column.
- Publication Part Number: A02408
- Created: 11 May 2010
- 906 KB
Publication Part Number | A02408 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W VF-624ms column separates 27 residual solvents in 40 minutes.
- Publication Part Number: A02400
- Created: 11 May 2010
- 807 KB
Publication Part Number | A02400 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|