Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Injection Technique
-
- Language
-
Language
Applied Filters
必威体育登录手机The Agilent J&W CP-Wax 57 CB phase shows excellent stability and selectivity for the analysis of 14 volatile compounds in water-alcohol mixtures by gas chromatography in 14 mi
- Publication Part Number: A01908
- Created: 30 Nov 2015
- 973 KB
Publication Part Number | A01908 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-WAX 57 CB column provides a unique selectivity in the analysis of 20 impurities in a whisky in 37 minutes.
- Publication Part Number: A01539
- Created: 30 Nov 2015
- 1 MB
Publication Part Number | A01539 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC with an Agilent J&W CP-Wax 57 CB column delivers excellent selectivity in the analysis of 25 impurities in an alcoholic beverage in 37 minutes.
- Publication Part Number: A01540
- Created: 30 Nov 2015
- 1 MB
Publication Part Number | A01540 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column identifies nine impurities in potable ethanol in 30 minutes.
- Publication Part Number: A01320
- Created: 30 Nov 2015
- 871 KB
Publication Part Number | A01320 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
HJ
- Publication Part Number: SI-00940
- Created: 05 Dec 2011
- 164 KB
Publication Part Number | SI-00940 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
UofG
- Publication Part Number: SI-00989
- Created: 05 Dec 2011
- 270 KB
Publication Part Number | SI-00989 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates 32 solvents in 44 minutes, according to USP 467.
- Publication Part Number: A01546
- Created: 31 Oct 2011
- 892 KB
Publication Part Number | A01546 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates eight alcohols in red wine in 16 minutes.
- Publication Part Number: A0706
- Created: 31 Oct 2011
- 521 KB
Publication Part Number | A00706 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 27 aromas in a wine sample in 14 minutes.
- Publication Part Number: A01461
- Created: 31 Oct 2011
- 810 KB
Publication Part Number | A01461 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with the Agilent J&W CP-Wax 57 CB phase separates ten volatiles in ethanol in ten minutes.
- Publication Part Number: A02331
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02331 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Carbowax 400 for Volatiles in Alcohol column separates eight alcohols and esters in a test mixture in eight minutes.
- Publication Part Number: A0431
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00431 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 19 components in Darjeeling tea in 40 minutes.
- Publication Part Number: A1030
- Created: 31 Oct 2011
- 690 KB
Publication Part Number | A01030 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC analysis of 26 solvents used in inks is accomplished in 35 minutes with an Agilent J&W Select 624 CB column.
- Publication Part Number: A02233
- Created: 31 Oct 2011
- 742 KB
Publication Part Number | A02233 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Carbowax 400 for Volatiles in Alcohol column separates 10 volatiles in ethanol in seven minutes.
- Publication Part Number: A0432
- Created: 31 Oct 2011
- 644 KB
Publication Part Number | A00432 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-1301 column separates 26 residual solvents in 49 minutes.
- Publication Part Number: A01266
- Created: 31 Oct 2011
- 808 KB
Publication Part Number | A01266 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 17 C1 to C7 alcohols in five minutes.
- Publication Part Number: A00009
- Created: 31 Oct 2011
- 339 KB
Publication Part Number | A00009 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 2 CB column separates ten oxygenates in 11 minutes.
- Publication Part Number: A0904
- Created: 31 Oct 2011
- 723 KB
Publication Part Number | A00904 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using splitless injection with an Agilent J&W PoraBOND Q column separates 17 polar solvents in a water sample in 18 minutes.
- Publication Part Number: A01428
- Created: 31 Oct 2011
- 715 KB
Publication Part Number | A01428 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W Lowox column separates oxygenates in a C1 to C6 hydrocarbon matrix in 23 minutes.
- Publication Part Number: A01362
- Created: 31 Oct 2011
- 887 KB
Publication Part Number | A01362 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 26 pharmacopoeia-specified solvents in 30 minutes.
- Publication Part Number: A01304
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A01304 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|