Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Method
-
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 14 drugs from emergency toxicology plasma extracts in eight minutes.
- Publication Part Number: A0321
- Created: 19 May 2015
- 2 MB
Publication Part Number | A00321 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates esmolol and flumolol in whole blood in 25 minutes.
- Publication Part Number: A0320
- Created: 19 May 2015
- 1 MB
Publication Part Number | A00320 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent CP-Sil 8 CB column separates ten chlorinated solvents in nine minutes
- Publication Part Number: A00720
- Created: 23 June 2014
- 708 KB
Publication Part Number | A00720 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using Agilent J&W CP-Sil 5 CB and CP-Sil 8 CB columns separates 32 components from the thermal desorption of a potential oil-bearing rock.
- Publication Part Number: A00059
- Created: 31 Oct 2013
- 827 KB
Publication Part Number | A00059 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 42 C1 to C10 aromatic hydrocarbons in 23 minutes.
- Publication Part Number: A0351
- Created: 31 Oct 2011
- 911 KB
Publication Part Number | A00351 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 82 pollutants according to EPA 625 in 65 minutes.
- Publication Part Number: A0789
- Created: 31 Oct 2011
- 801 KB
Publication Part Number | A00789 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 42 organic solvents in 35 minutes.
- Publication Part Number: A0493
- Created: 31 Oct 2011
- 671 KB
Publication Part Number | A00493 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates chemical warfare agents in 24 minutes.
- Publication Part Number: A01617
- Created: 31 Oct 2011
- 489 KB
Publication Part Number | A01617 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 16 C1 to C7 hydrocarbons in natural gas in 25 minutes.
- Publication Part Number: A0117
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A00117 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 19 alkylbenzenes in 18 minutes.
- Publication Part Number: A0301
- Created: 31 Oct 2011
- 868 KB
Publication Part Number | A00301 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 20 polycyclic aromatic hydrocarbons according to EPA 8100 in 45 minutes.
- Publication Part Number: A0801
- Created: 31 Oct 2011
- 553 KB
Publication Part Number | A00801 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 22 components in a raw material for plastic packaging in 20 minutes.
- Publication Part Number: A1016
- Created: 31 Oct 2011
- 648 KB
Publication Part Number | A01016 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 40 polychlorinated biphenyls in the liver of an oyster catcher in 56 minutes.
- Publication Part Number: A0337
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00337 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 28 C1 to C6 halogenated hydrocarbons in drinking water in 20 minutes.
- Publication Part Number: A0303
- Created: 31 Oct 2011
- 309 KB
Publication Part Number | A00303 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 18 C5 to C10 halogenated hydrocarbons according to EPA 8120 in 90 minutes.
- Publication Part Number: A0802
- Created: 31 Oct 2011
- 552 KB
Publication Part Number | A00802 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sill 8 CB column is used to analyze chlorine by employing its reaction with acetone, giving results in ten minutes.
- Publication Part Number: A0897
- Created: 31 Oct 2011
- 591 KB
Publication Part Number | A00897 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 11 urinary phenols as acetate esters in 15 minutes.
- Publication Part Number: A0711
- Created: 31 Oct 2011
- 671 KB
Publication Part Number | A00711 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates five haloethers according to EPA 611 in 25 minutes.
- Publication Part Number: A0787
- Created: 31 Oct 2011
- 568 KB
Publication Part Number | A00787 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five underivatized drugs of abuse in a ‘brown powder' sample in 15 minutes.
- Publication Part Number: A01391
- Created: 31 Oct 2011
- 581 KB
Publication Part Number | A01391 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column identifies 15 components in a sample of water with organoleptic claims, in 22 minutes.
- Publication Part Number: A1014
- Created: 31 Oct 2011
- 540 KB
Publication Part Number | A01014 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|