必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates esmolol and flumolol in whole blood in 25 minutes.
- Publication Part Number: A0320
- Created: 19 May 2015
- 1 MB
Publication Part Number | A00320 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Substituting the VF-1701 Pesticides column can be used in place of the Restek Rtx-CLPesticides1 column and the VF-5 Pesticides column.
- Publication Part Number: SI-00924
- Created: 03 Feb 2014
- 177 KB
Publication Part Number | SI-00924 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
English (United States) | Complete (PDF) |
---|
必威体育登录手机An Agilent 7890B GC system configured with three detectors was used for the analysis of pesticides in water.
- Publication Part Number: 5991-2787EN
- Created: 05 Aug 2013
- 1 MB
Publication Part Number | 5991-2787EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Application note for GC-μECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil
- Publication Part Number: 5990-5553EN
- Created: 06 Jan 2012
- 1 MB
Publication Part Number | 5990-5553EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Application note for GC/μECD Analysis and Confirmation of PCBs in Fish Tissue with Agilent J&W DB-35ms and DB-XLB GC Columns
- Publication Part Number: 5990-6236EN
- Created: 06 Jan 2012
- 641 KB
Publication Part Number | 5990-6236EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Two Agilent GC columns are used in the analysis of polychlorinated biphenyls!必威体育登录手机a PDMS phase equivalent to Agilent J&W VF-1ms, and an Agilent J&W VF-23ms.
- Publication Part Number: A02095
- Created: 31 Oct 2011
- 807 KB
Publication Part Number | A02095 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 15 chlorinated pesticides in 15 minutes.
- Publication Part Number: A0360
- Created: 31 Oct 2011
- 942 KB
Publication Part Number | A00360 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB for Pesticides column separates 15 organochlorine pesticides in 27 minutes.
- Publication Part Number: A1091
- Created: 31 Oct 2011
- 707 KB
Publication Part Number | A01091 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select for PCB column separates nine polychlorinated biphenyls in 17 minutes.
- Publication Part Number: A01636
- Created: 31 Oct 2011
- 380 KB
Publication Part Number | A01636 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC with an Agilent J&W CP-Sil 13 CB for Halocarbons column separates 1,2 dibromoethane and 1,2 dibromo-3-chloropropane according to EPA 504 in seven minutes.
- Publication Part Number: A0777
- Created: 31 Oct 2011
- 338 KB
Publication Part Number | A00777 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of dioxins and benzofurans by GC, with a PDMS phase equivalent to J&W Agilent VF-1ms, and Agilent J&W VF-23ms, is accomplished in 90 minutes.
- Publication Part Number: A02096
- Created: 31 Oct 2011
- 598 KB
Publication Part Number | A02096 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC analysis of 16 organochlorine pesticides according to EPA 625 is achieved in less than 23 minutes using Agilent J&W VF-5ms EZ-Guard columns.
- Publication Part Number: A02208
- Created: 31 Oct 2011
- 886 KB
Publication Part Number | A02208 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB for Pesticides column separates 15 organochlorine pesticides in 39 minutes.
- Publication Part Number: A1092
- Created: 31 Oct 2011
- 672 KB
Publication Part Number | A01092 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates nine volatile halogen compounds in a water sample.
- Publication Part Number: A00062
- Created: 31 Oct 2011
- 691 KB
Publication Part Number | A00062 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select for PCB column separates five polychlorinated biphenyls in minced pork in 12 minutes.
- Publication Part Number: A01542
- Created: 31 Oct 2011
- 378 KB
Publication Part Number | A01542 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 40 polychlorinated biphenyls in the liver of an oyster catcher in 56 minutes.
- Publication Part Number: A0337
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00337 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 18 C5 to C10 halogenated hydrocarbons according to EPA 8120 in 90 minutes.
- Publication Part Number: A0802
- Created: 31 Oct 2011
- 552 KB
Publication Part Number | A00802 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of polychlorinated biphenyls in sewage sludge uses an Agilent Bond Elut PCB for solid phase extraction and GC with an Agilent J&W CP-Sil5/C18 CB for PCB column.
- Publication Part Number: A01576
- Created: 31 Oct 2011
- 709 KB
Publication Part Number | A01576 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB/C18 column separates more than 37 polychlorinated biphenyls in Aroclor 1260 in 150 minutes.
- Publication Part Number: A0977
- Created: 31 Oct 2011
- 754 KB
Publication Part Number | A00977 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 27 chloropesticides and polychlorinated biphenyls in 22 minutes.
- Publication Part Number: A00596
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A00596 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|