Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Language
-
Language
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 14 drugs from emergency toxicology plasma extracts in eight minutes.
- Publication Part Number: A0321
- Created: 19 May 2015
- 2 MB
Publication Part Number | A00321 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates seven pesticides in potato, radish, and cabbage lettuce in 40 minutes.
- Publication Part Number: A0703
- Created: 31 Oct 2011
- 926 KB
Publication Part Number | A00703 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates 11 triazine herbicides in 30 minutes.
- Publication Part Number: A01227
- Created: 31 Oct 2011
- 372 KB
Publication Part Number | A01227 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 13 tricyclic antidepressants in plasma in 14 minutes.
- Publication Part Number: A0245
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00245 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 25 organophosphorus pesticides according to EPA 8140 and 8141 in 31 minutes.
- Publication Part Number: A0615
- Created: 31 Oct 2011
- 867 KB
Publication Part Number | A00615 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates 11 urea herbicides, derivatized with methyl iodide, in 30 minutes.
- Publication Part Number: A01228
- Created: 31 Oct 2011
- 413 KB
Publication Part Number | A01228 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separate 58 organophosphorus pesticides in 26 minutes.
- Publication Part Number: A01348
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A01348 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates eight nitrogen-containing herbicides in 30 minutes.
- Publication Part Number: A01229
- Created: 31 Oct 2011
- 358 KB
Publication Part Number | A01229 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC with Agilent J&W CP-Sil 8 CB and PFPD is a highly sensitive and selective system capable of detecting a number of elements, 13 of these with ultimate selectivity.
- Publication Part Number: A01608
- Created: 31 Oct 2011
- 4 MB
Publication Part Number | A01608 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates 18 underivatized drugs of abuse in a standard mixture in 15 minutes.
- Publication Part Number: A01390
- Created: 31 Oct 2011
- 546 KB
Publication Part Number | A01390 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Sil 8 column separates 20 underivatized drugs in 18 minutes.
- Publication Part Number: A0116
- Created: 31 Oct 2011
- 720 KB
Publication Part Number | A00116 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five underivatized drugs of abuse in an ecstasy tablet in 15 minutes.
- Publication Part Number: A01392
- Created: 31 Oct 2011
- 540 KB
Publication Part Number | A01392 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 39 fungicides in 30 minutes.
- Publication Part Number: A0610
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00610 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT for Amines column separates 10 volatile amines in 10 minutes.
- Publication Part Number: A0898
- Created: 31 Oct 2011
- 580 KB
Publication Part Number | A00898 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 17 organophosphorus pesticides with thioether groups in 24 minutes.
- Publication Part Number: A0614
- Created: 31 Oct 2011
- 728 KB
Publication Part Number | A00614 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five underivatized drugs of abuse in a ‘brown powder' sample in 15 minutes.
- Publication Part Number: A01391
- Created: 31 Oct 2011
- 581 KB
Publication Part Number | A01391 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 11 triazine herbicides in 15 minutes.
- Publication Part Number: A0613
- Created: 31 Oct 2011
- 693 KB
Publication Part Number | A00613 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates three organophosphate pesticides in lemon oil in 16 minutes.
- Publication Part Number: A0356
- Created: 31 Oct 2011
- 652 KB
Publication Part Number | A00356 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil Val column separates enantiomers of the vasodilator cromakalim in 14 minutes.
- Publication Part Number: A0688
- Created: 31 Oct 2011
- 866 KB
Publication Part Number | A00688 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column uses headspace analysis to identify cyanides in blood in less than four minutes.
- Publication Part Number: A01529
- Created: 31 Oct 2011
- 566 KB
Publication Part Number | A01529 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|