Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
Chemical Group
- Language
-
Language
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates C18 to C90 hydrocarbons in a heavy wax sample in 44 minutes.
- Publication Part Number: A01444
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01444 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates nine components in a polywax 655 in 95 minutes.
- Publication Part Number: A0772
- Created: 31 Oct 2011
- 666 KB
Publication Part Number | A00772 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography and an Agilent J&W CP-SimDist UltiMetal column separate hydrocarbons according to IP PM-CX/98.
- Publication Part Number: A01335
- Created: 31 Oct 2011
- 956 KB
Publication Part Number | A01335 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates C12 to C110 hydrocarbon components in Polywax 655 in 4 minutes.
- Publication Part Number: A0649
- Created: 31 Oct 2011
- 941 KB
Publication Part Number | A00649 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates C5 to C44 hydrocarbons in a standard mixture in 36 minutes.
- Publication Part Number: A0651
- Created: 31 Oct 2011
- 730 KB
Publication Part Number | A00651 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates five components in a paraffin wax in 50 minutes.
- Publication Part Number: A0773
- Created: 31 Oct 2011
- 545 KB
Publication Part Number | A00773 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates 16 C8 to C40 hydrocarbons in 12 minutes.
- Publication Part Number: A0998
- Created: 31 Oct 2011
- 604 KB
Publication Part Number | A00998 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC with Agilent J&W CP-Sil 5 CB Low Bleed/MS separates 14 components in a sample of mineral oil in 35 minutes, according to the Dutch standard NVN 6678.
- Publication Part Number: A01322
- Created: 31 Oct 2011
- 787 KB
Publication Part Number | A01322 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent CP-SimDist UltiMetal column separates 11 components in a petroleum wax in 95 minutes.
- Publication Part Number: A0774
- Created: 31 Oct 2011
- 575 KB
Publication Part Number | A00774 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist CB column separates 11 components of mineral oil in a soil sample in less than 15 minutes.
- Publication Part Number: A01105
- Created: 31 Oct 2011
- 505 KB
Publication Part Number | A01105 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
454D.jpg
- Publication Part Number: 19095Z-023
- Created: 08 May 2018
- 42 KB
- JPG
Publication Part Number | 454D | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
454C.jpg
- Publication Part Number: 19091J-015
- Created: 08 May 2018
- 43 KB
- JPG
Publication Part Number | 454C | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|