Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Injection Technique
- Instrument
-
必威体育登录手机Agilent 7683B Automatic Liquid sampler (2)
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Fifteen days' exposure to oxygen in GC carrier gas ruptured the filament and affected column bleed, retention time drift, endrin/DDT breakdown, S/N, and EMV.
- Publication Part Number: 5991-4110EN
- Created: 01 Mar 2014
- 266 KB
Publication Part Number | 5991-4110EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Application note for the multi-residue analysis of PAHs, PCBs and OCPs using an Agilent FactorFour VF-35ms Column
- Publication Part Number: SI-2396
- Created: 30 Jan 2014
- 274 KB
Publication Part Number | SI-02396 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
A highly sensitive and reliable method has been developed for 51 nonpolar compounds in potable water, and PBDEs, PAHs, and diazinon in wastewater.
- Publication Part Number: 5991-1553EN
- Created: 16 Jan 2013
- 1 MB
Publication Part Number | 5991-1553EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
A GC/MS/MS method for the analysis of pesticide residues in fruits and vegetables was developed, optimized, and successfully implemented
- Publication Part Number: 5991-1054EN
- Created: 11 Oct 2012
- 641 KB
Publication Part Number | 5991-1054EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机Agilent J&W DB-CLP1 and DB-CLP2 column pair performs rapid, high-resolution separations of CLP pesticides, US EPA methods, and similar semi-volatile mixtures
- Publication Part Number: 5991-0541EN
- Created: 06 Aug 2012
- 482 KB
Publication Part Number | 5991-0541EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Compared to other vendor's columns, Agilent J&W DB-CLP1/DB-CLP2 provides better combinations of faster analysis times and fewer coelutions,
- Publication Part Number: 5991-0615EN
- Created: 02 Aug 2012
- 2 MB
Publication Part Number | 5991-0615EN | |||||||
---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||
Instrument |
|
|||||||
Analytical Technique | Technique |
|
||||||
Injection |
|
|||||||
Detection |
|
|||||||
Sample | Chemical Group |
|
||||||
Sample Matrix |
|
必威体育登录手机Agilent J&W DB-CLP1 and DB-CLP2 columns separated organohalides from water, while enabling reliable detection at and below EU and EPA maximum contaminant levels.
- Publication Part Number: 5991-0207EN
- Created: 29 Mar 2012
- 922 KB
Publication Part Number | 5991-0207EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Application note for sub μg/L Level Analysis of Chlorinated Pesticide and Herbicide Analysis in Water by GC/μECD
- Publication Part Number: 5990-9735EN
- Created: 20 Jan 2012
- 1 MB
Publication Part Number | 5990-9735EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
Application note for GC-μECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil
- Publication Part Number: 5990-5553EN
- Created: 06 Jan 2012
- 1 MB
Publication Part Number | 5990-5553EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|