Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Detection Technique
- Injection Technique
-
- Instrument
Instrument
- Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates C1 to C3 hydrocarbons and carbon monoxide/dioxide in six minutes.
- Publication Part Number: A01287
- Created: 18 Oct 2021
- 110 KB
Publication Part Number | A01287 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
7890B Packed Column Refinery Gas analysis using the G3507A Large Valve Oven
- Publication Part Number: 5991-3535EN
- Created: 25 Nov 2013
- 1 MB
Publication Part Number | 5991-3535EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Complete Refinery Gas analysis in less than 8 minutes using the G3507A Large valve Oven
- Publication Part Number: 5991-3534EN
- Created: 21 Nov 2013
- 254 KB
Publication Part Number | 5991-3534EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent J&W PLOT PT columns with permanent integral traps show no spikes, indicating effective particle retention, have no potential for leaks and the ends can be trimmed.
- Publication Part Number: 5991-2975EN
- Created: 26 Aug 2013
- 638 KB
Publication Part Number | 5991-2975EN | ||||||||
---|---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||||
Instrument |
|
||||||||
Analytical Technique | Technique |
|
|||||||
Injection |
|
||||||||
Detection |
|
||||||||
Sample | Chemical Group |
|
|||||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Describing the detailed separation of C1-C5 Light Hydrocarbons on CP-Al2O3/Na2SO4.
- Publication Part Number: SI-02644
- Created: 27 Sep 2012
- 150 KB
Publication Part Number | SI-02644 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 53 C1 to C9 hydrocarbons and C6 to C9 aromatics in 40 minutes.
- Publication Part Number: A0604
- Created: 31 Oct 2011
- 877 KB
Publication Part Number | A00604 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 21 light hydrocarbons in 30 minutes.
- Publication Part Number: A01454
- Created: 31 Oct 2011
- 626 KB
Publication Part Number | A01454 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT S column separates 21 light hydrocarbons in 14 minutes.
- Publication Part Number: A01455
- Created: 31 Oct 2011
- 669 KB
Publication Part Number | A01455 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column resolves 14 C1 to C6 hydrocarbon impurities in propylene in 20 minutes.
- Publication Part Number: A01097
- Created: 31 Oct 2011
- 613 KB
Publication Part Number | A01097 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC with Agilent J&W CarboBOND separates eight C1-C3 hydrocarbons in less than seven minutes.Water elutes before propane with virtually no effect on retention time.
- Publication Part Number: A01651
- Created: 31 Oct 2011
- 812 KB
Publication Part Number | A01651 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT S column separates eight C1 to C3 hydrocarbons in 10 minutes.
- Publication Part Number: A0452
- Created: 31 Oct 2011
- 603 KB
Publication Part Number | A00452 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent CP-Al2O3/KCl column separates 16 C1 to C4 hydrocarbons in 100 seconds.
- Publication Part Number: A0273
- Created: 31 Oct 2011
- 614 KB
Publication Part Number | A00273 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 16 C1 to C4 light hydrocarbons in 20 minutes.
- Publication Part Number: A00591
- Created: 31 Oct 2011
- 376 KB
Publication Part Number | A00591 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates 14 impurities in propylene in 25 minutes.
- Publication Part Number: A01353
- Created: 31 Oct 2011
- 682 KB
Publication Part Number | A01353 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column provides high resolution of 14 C1 to C4 hydrocarbons in seven minutes.
- Publication Part Number: A1095
- Created: 31 Oct 2011
- 561 KB
Publication Part Number | A01095 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 39 C1 to C4 nitriles and C1 to C5 hydrocarbons in 60 minutes.
- Publication Part Number: A00572
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00572 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|