Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Injection Technique
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
7890B Packed Column Refinery Gas analysis using the G3507A Large Valve Oven
- Publication Part Number: 5991-3535EN
- Created: 25 Nov 2013
- 1 MB
Publication Part Number | 5991-3535EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Complete Refinery Gas analysis in less than 8 minutes using the G3507A Large valve Oven
- Publication Part Number: 5991-3534EN
- Created: 21 Nov 2013
- 254 KB
Publication Part Number | 5991-3534EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 53 C1 to C9 hydrocarbons and C6 to C9 aromatics in 40 minutes.
- Publication Part Number: A0604
- Created: 31 Oct 2011
- 877 KB
Publication Part Number | A00604 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 39 C1 to C4 nitriles and C1 to C5 hydrocarbons in 60 minutes.
- Publication Part Number: A00572
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00572 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 36 C5 to C12 PONA hydrocarbons according to ASTM D5134 in 90 minutes.
- Publication Part Number: A0751
- Created: 31 Oct 2011
- 780 KB
Publication Part Number | A00751 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 28 C5 monomers in 25 minutes.
- Publication Part Number: A0716
- Created: 31 Oct 2011
- 881 KB
Publication Part Number | A00716 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates over 165 C4 to C12 hydrocarbons in 130 minutes.
- Publication Part Number: A00602
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00602 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q-HT column separates 10 C3 to C6 hydrocarbons in 12 minutes.
- Publication Part Number: A01298
- Created: 31 Oct 2011
- 730 KB
Publication Part Number | A01298 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 35 C1 to C5 hydrocarbons in exhaust from a gasoline engine in 42 minutes.
- Publication Part Number: A00739
- Created: 31 Oct 2011
- 765 KB
Publication Part Number | A00739 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 24 C1 to C5 hydrocarbons in 27 minutes.
- Publication Part Number: A0611
- Created: 31 Oct 2011
- 957 KB
Publication Part Number | A00611 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|