Refine Results
- 必威体育赛事投注
-
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Detection Technique
-
- Instrument
Instrument
- Analysis Platform
-
Product
- Language
-
Language
必威体育登录手机This Application Note shows the expansion of the Agilent 1260 Infinity Bio-inert Quaternary LC System with the Agilent 1260 Infinity Multi-Detector GPC/SEC System
- Publication Part Number: 5991-2884EN
- Created: 30 Apr 2015
- 1 MB
Publication Part Number | 5991-2884EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机This Application Note shows the determination of protein molecular weightand size, together with linear quantification using the Agilent 1260 Infinity Multi-Detector Bio-SEC S
- Publication Part Number: 5991-3955EN
- Created: 01 Mar 2014
- 957 KB
Publication Part Number | 5991-3955EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Russian (Russia) | Complete (PDF) |
---|
Columns containing weak cation-exchange stationary phases offer a degree of versability when used for separation of positively charged proteins.
- Publication Part Number: 5990-9628EN
- Created: 01 Aug 2013
- 1 MB
Publication Part Number | 5990-9628EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Ion exchange is a commonly used technique for the separation of complex protein mixtures.
- Publication Part Number: 5990-9931EN
- Created: 01 Aug 2013
- 2 MB
Publication Part Number | 5990-9931EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Column choice in SEC depends on column resolving range, identified by calibration with standards appropriate to analyte type, molecular weight range, and size in solution.
- Publication Part Number: 5991-2463EN
- Created: 14 May 2013
- 117 KB
Publication Part Number | 5991-2463EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Agilent Captiva Premium PES syringe filters are compared with non-Agilent PES and PVDF syringe filters.
- Publication Part Number: 5991-1308EN
- Created: 26 Oct 2012
- 293 KB
Publication Part Number | 5991-1308EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Size exclusion chromatography (SEC) can be used for investigating the effect of temperature on a series of globular proteins to identify unfolded and/or aggregate species.
- Publication Part Number: 5990-8140EN
- Created: 10 Sep 2012
- 426 KB
Publication Part Number | 5990-8140EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Analysis of globulins in denaturing and non-denaturing conditions using gel filtration chromatography and a ProSEC 300S column
- Publication Part Number: 5990-8141EN
- Created: 06 Sep 2012
- 425 KB
Publication Part Number | 5990-8141EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
A mixture of standard proteins was used to determine the resolution characteristics of the columns...
- Publication Part Number: 5990-8895EN
- Created: 13 Sep 2011
- 703 KB
Publication Part Number | 5990-8895EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Applicaiton note for the effect of NaCl concentration on protein size exclusion chromatography
- Publication Part Number: 5990-8139EN
- Created: 18 May 2011
- 642 KB
Publication Part Number | 5990-8139EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Application note for the characterization of monoclonal antibodies on the Agilent 1260 Infinity Bio-inert Quaternary LC by SEC using the Agilent BioSEC columns
- Publication Part Number: 5990-6414EN
- Created: 01 Feb 2011
- 996 KB
Publication Part Number | 5990-6414EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
The number of proteins and antibodies in drug development and in clinical phase trials is growing rapidly.
- Publication Part Number: 5989-9899EN
- Created: 25 Nov 2008
- 110 KB
Publication Part Number | 5989-9899EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
479B.jpg
- Publication Part Number: 884973-901
- Created: 08 May 2018
- 41 KB
- JPG
Publication Part Number | 479B | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
480B.jpg
- Publication Part Number: 884973-901
- Created: 08 May 2018
- 44 KB
- JPG
Publication Part Number | 480B | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Publication Part Number | PS2_025525 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|