Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Instrument
Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机An Agilent J&W DB-624UI column was compared with non-Agilent 624 phases, delivering better performance for C3 through C8 volatiles.
- Publication Part Number: 5991-1441EN
- Created: 08 Nov 2012
- 622 KB
Publication Part Number | 5991-1441EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Agilent's new deactivation of the 6% cyanopropyl dimethylpolysiloxane (624) phase significantly improves acid performance and maintains very good performance.
- Publication Part Number: 5991-0845EN
- Created: 31 July 2012
- 2 MB
Publication Part Number | 5991-0845EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (United States) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography using split injection and an Agilent J&W CP-Wax 57 CB column separates 26 alcohols and esters in a sample of whisky in 43 minutes.
- Publication Part Number: A00052
- Created: 31 Oct 2011
- 745 KB
Publication Part Number | A00052 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 52 CB column identifies dimethylsulfide in a sample of beer in 15 minutes.
- Publication Part Number: A00006
- Created: 31 Oct 2011
- 449 KB
Publication Part Number | A00006 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Carbowax 400 for Volatiles in Alcohol column separates 11 alcohols and esters in beer in 12 minutes.
- Publication Part Number: A0620
- Created: 31 Oct 2011
- 637 KB
Publication Part Number | A00620 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|