UHPLC and LC/MS analysis of carbonyls by Poroshell 120 EC-C18 gave good selectivity and resolution.
- Publication Part Number: 5991-2125EN
- Created: 19 Mar 2013
- 785 KB
Publication Part Number | 5991-2125EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
This Application Note describes the successful analysis of 13 DNPH-derivatized aldehydes and ketones using the 1220 Infinity Gradient LC system with built-in DAD
- Publication Part Number: 5991-1545EN
- Created: 01 Jan 2013
- 717 KB
Publication Part Number | 5991-1545EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC analyzes acrolein in air in 20 seconds.
- Publication Part Number: A0876
- Created: 31 Oct 2011
- 261 KB
Publication Part Number | A00876 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates components in formalin headspace gas in eight minutes.
- Publication Part Number: A0624
- Created: 31 Oct 2011
- 546 KB
Publication Part Number | A00624 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB for Halocarbons column separates 47 solvents and other volatiles according to EPA 8240 in 42 minutes.
- Publication Part Number: A0804
- Created: 31 Oct 2011
- 799 KB
Publication Part Number | A00804 | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates acrolein and acrylonitrile according to EPA 603 in ten minutes.
- Publication Part Number: A0782
- Created: 31 Oct 2011
- 375 KB
Publication Part Number | A00782 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|