必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 120 semivolatiles according to EPA 8270 in 94 minutes.
- Publication Part Number: A0805
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A00805 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 19 polyaromatic hydrocarbons and phenols in 22 minutes.
- Publication Part Number: A00598
- Created: 31 Oct 2011
- 811 KB
Publication Part Number | A00598 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Sil 8 column separates 20 polycyclic aromatic hydrocarbons in 20 minutes.
- Publication Part Number: A0125
- Created: 31 Oct 2011
- 847 KB
Publication Part Number | A00125 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机An Agilent J&W VF-200ms GC column separates eight nitro compounds in 20 minutes.
- Publication Part Number: A02094
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A02094 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB Low Bleed/MS column separates 29 C8 to C17aromatic hydrocarbons in 30 minutes.
- Publication Part Number: A01264
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01264 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 82 pollutants according to EPA 625 in 65 minutes.
- Publication Part Number: A0789
- Created: 31 Oct 2011
- 801 KB
Publication Part Number | A00789 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 31 C6 to C13 polycyclic aromatic hydrocarbons in 51 minutes.
- Publication Part Number: A0652
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00652 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Analysis of eight nitro compounds by gas chromatography using an Agilent J&W VF-1301ms column in less than 25 minutes.
- Publication Part Number: A02415
- Created: 11 May 2010
- 541 KB
Publication Part Number | A02415 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||