Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Injection Technique
-
- Instrument
-
必威体育登录手机Agilent 7683B Automatic Liquid sampler (3)
Instrument
- Method
-
Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography and an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separate six alcohols and glycols in a water sample in seven minutes.
- Publication Part Number: A01330
- Created: 30 Nov 2015
- 860 KB
Publication Part Number | A01330 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight C2 to C7 free fatty acids in water in seven minutes.
- Publication Part Number: A0281
- Created: 20 June 2014
- 711 KB
Publication Part Number | A00281 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机The exceptional inertness of Agilent J&W DB-5ms Ultra Inert GC columns delivered superior results for basic compounds in a comparison of -5ms phases.
- Publication Part Number: 5991-4626EN
- Created: 13 May 2014
- 224 KB
Publication Part Number | 5991-4626EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机An Agilent 7820 GC method for MTBE residue in water and soil was established.
- Publication Part Number: 5991-4191EN
- Created: 28 Mar 2014
- 122 KB
Publication Part Number | 5991-4191EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Fifteen days' exposure to oxygen in GC carrier gas ruptured the filament and affected column bleed, retention time drift, endrin/DDT breakdown, S/N, and EMV.
- Publication Part Number: 5991-4110EN
- Created: 01 Mar 2014
- 266 KB
Publication Part Number | 5991-4110EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 21 phenols according to EPA 8040 in 24 minutes.
- Publication Part Number: A1001
- Created: 31 Oct 2013
- 692 KB
Publication Part Number | A01001 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 19 chlorinated solvents in 12 minutes.
- Publication Part Number: A01415
- Created: 31 Oct 2013
- 501 KB
Publication Part Number | A01415 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机An Agilent 7890B GC system configured with three detectors was used for the analysis of pesticides in water.
- Publication Part Number: 5991-2787EN
- Created: 05 Aug 2013
- 1 MB
Publication Part Number | 5991-2787EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
In China, since 2001, civil building engineering has been regulated by GB50325.
- Publication Part Number: 5991-1536EN
- Created: 05 Mar 2013
- 1 MB
Publication Part Number | 5991-1536EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Agilent's new deactivation of the 6% cyanopropyl dimethylpolysiloxane (624) phase significantly improves acid performance and maintains very good performance.
- Publication Part Number: 5991-0845EN
- Created: 31 July 2012
- 2 MB
Publication Part Number | 5991-0845EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates eight C1 to C2 halogenated hydrocarbons in water in 12.5 minutes.
- Publication Part Number: A1019
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A01019 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates a test mix of 22 volatile organic compounds in water in 25 minutes.
- Publication Part Number: A1021
- Created: 31 Oct 2011
- 701 KB
Publication Part Number | A01021 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column separates six volatile aromatic hydrocarbons at low concentrations in water in 13 minutes.
- Publication Part Number: A0219
- Created: 31 Oct 2011
- 469 KB
Publication Part Number | A00219 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates nine chlorinated volatiles and hydrocarbons in 14 minutes.
- Publication Part Number: A01289
- Created: 31 Oct 2011
- 806 KB
Publication Part Number | A01289 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC analysis of 14 base neutrals with an Agilent J&W VF-200ms column achieves a separation in 28 minutes.
- Publication Part Number: A02200
- Created: 31 Oct 2011
- 617 KB
Publication Part Number | A02200 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates seven C3 to C9 volatile alcohols in 12 minutes.
- Publication Part Number: A0176
- Created: 31 Oct 2011
- 542 KB
Publication Part Number | A00176 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates four glycols (ppm level) in water in 13 minutes.
- Publication Part Number: A0712
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00712 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates enantiomers of chlorophenol in 12 minutes.
- Publication Part Number: A0994
- Created: 31 Oct 2011
- 536 KB
Publication Part Number | A00994 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 42 C1 to C10 aromatic hydrocarbons in 23 minutes.
- Publication Part Number: A0351
- Created: 31 Oct 2011
- 911 KB
Publication Part Number | A00351 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates ten chlorinated phenols in 14 minutes.
- Publication Part Number: A0901
- Created: 31 Oct 2011
- 706 KB
Publication Part Number | A00901 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|