Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Method
-
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W VF-Xms column separates 12 phthalate esters in 40 minutes using the EPA 8060 method.
- Publication Part Number: A01966
- Created: 31 Oct 2011
- 864 KB
Publication Part Number | A01966 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 13base neutrals according to EPA8270 in 20 minutes.
- Publication Part Number: A2090
- Created: 31 Oct 2011
- 503 KB
Publication Part Number | A02090 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 16 organochlorine pesticides according to EPA625 in 27 minutes.
- Publication Part Number: A02092
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A02092 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of eight chlorinated hydrocarbons uses an Agilent J&W VF-200ms column to achieve a separation in 22 minutes.
- Publication Part Number: A02205
- Created: 31 Oct 2011
- 397 KB
Publication Part Number | A02205 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 14base neutrals in 20 minutes.
- Publication Part Number: A02089
- Created: 31 Oct 2011
- 484 KB
Publication Part Number | A02089 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with ion trap and an Agilent J&W VF-Xms column separates 16 polycyclic aromatic hydrocarbons in 18 minutes.
- Publication Part Number: A01967
- Created: 31 Oct 2011
- 587 KB
Publication Part Number | A01967 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates eight basic aromatics in 25 minutes.
- Publication Part Number: A02093
- Created: 31 Oct 2011
- 423 KB
Publication Part Number | A02093 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of nine aromatic volatiles uses an Agilent J&W VF-200ms column to achieve a separation in less than 12 minutes.
- Publication Part Number: A02206
- Created: 31 Oct 2011
- 411 KB
Publication Part Number | A02206 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates nine nitrosamines according to EPA8270 in less than 20 minutes.
- Publication Part Number: A02091
- Created: 31 Oct 2011
- 402 KB
Publication Part Number | A02091 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS analysis of eight nitroaromatics and cyclic ketones according to EPA 8090, with an Agilent J&W VF-200ms column, is achieved in less than 20 minutes.
- Publication Part Number: A02097
- Created: 31 Oct 2011
- 427 KB
Publication Part Number | A02097 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Trace analysis of 17 pesticides using the Agilent J&W VF-17ms in 26 minutes.
- Publication Part Number: A02346
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02346 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|