Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Injection Technique
- Instrument
- Method
- Language
-
Language
Applied Filters
Fifteen days' exposure to oxygen in GC carrier gas ruptured the filament and affected column bleed, retention time drift, endrin/DDT breakdown, S/N, and EMV.
- Publication Part Number: 5991-4110EN
- Created: 01 Mar 2014
- 266 KB
Publication Part Number | 5991-4110EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates ten chlorinated pesticides according to EPA 505 in 37 minutes.
- Publication Part Number: A0913
- Created: 31 Oct 2011
- 661 KB
Publication Part Number | A00913 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for PCBs column separates 12 chlorinated pesticides according to EPA 505 in 23 minutes.
- Publication Part Number: A0778
- Created: 31 Oct 2011
- 558 KB
Publication Part Number | A00778 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 41 organic water pollutants according to EPA 525 in 50 minutes.
- Publication Part Number: A0781
- Created: 31 Oct 2011
- 797 KB
Publication Part Number | A00781 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 120 semivolatiles according to EPA 8270 in 94 minutes.
- Publication Part Number: A0805
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A00805 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|