Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Compounds
-
Compounds
- Detection Technique
- Instrument
- Method
- Language
-
Language
Applied Filters
The EPA 8330A analysis of nitroaromatics and nitramines explosive residues was improved by using a Poroshell 120 EC-CN column for confirmation and a Poroshell 120 EC-C18
- Publication Part Number: 5991-1682EN
- Created: 20 Dec 2012
- 542 KB
Publication Part Number | 5991-1682EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 13base neutrals according to EPA8270 in 20 minutes.
- Publication Part Number: A2090
- Created: 31 Oct 2011
- 503 KB
Publication Part Number | A02090 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS analysis of eight nitroaromatics and cyclic ketones according to EPA 8090, with an Agilent J&W VF-200ms column, is achieved in less than 20 minutes.
- Publication Part Number: A02097
- Created: 31 Oct 2011
- 427 KB
Publication Part Number | A02097 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机An Agilent J&W VF-200ms GC column separates eight nitro compounds in 20 minutes.
- Publication Part Number: A02094
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A02094 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates four nitroaromatics according to EPA 609 in 15 minutes.
- Publication Part Number: A0786
- Created: 31 Oct 2011
- 429 KB
Publication Part Number | A00786 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates eight basic aromatics in 25 minutes.
- Publication Part Number: A02093
- Created: 31 Oct 2011
- 423 KB
Publication Part Number | A02093 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|