Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
- Injection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Complete Refinery Gas analysis in less than 8 minutes using the G3507A Large valve Oven
- Publication Part Number: 5991-3534EN
- Created: 21 Nov 2013
- 254 KB
Publication Part Number | 5991-3534EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
This application note demonstrates the capabilities of the COX column with the 490 Micro GC.
- Publication Part Number: 5990-7054EN
- Created: 06 Sep 2012
- 610 KB
Publication Part Number | 5990-7054EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W CarboPLOT P7 column separates eight permanent gases in coke oven gas (detarred) in less than ten minutes.
- Publication Part Number: A0763
- Created: 31 Oct 2011
- 506 KB
Publication Part Number | A00763 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates five permanent gases in about five minutes.
- Publication Part Number: A00036
- Created: 31 Oct 2011
- 412 KB
Publication Part Number | A00036 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Application note for Permanent Gas Analysis – Separation of Argon and Oxygen on a MolSieve 5A Column using the Agilent 490 Micro GC
- Publication Part Number: 5990-8700EN
- Created: 27 July 2011
- 200 KB
Publication Part Number | 5990-8700EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Analysis of permenant gases using 10m Molsieve column for samples with a high % of oxygen.
- Publication Part Number: 5990-8527EN
- Created: 05 July 2011
- 340 KB
Publication Part Number | 5990-8527EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Application note for Fast Separation of Oxygen and Nitrogen on a MolSieve 5A Channel Using the Agilent 490 Micro GC
- Publication Part Number: 5990-8529EN
- Created: 28 June 2011
- 213 KB
Publication Part Number | 5990-8529EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|