Use Poroshell 120 EC-C18 for best peak shape and separation or Poroshell 120 Phenyl-Hexyl for selectivity to replace TLC with LC for USP metoprolol tartrate.
- Publication Part Number: 5991-4564EN
- Created: 06 May 2014
- 223 KB
Publication Part Number | 5991-4564EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机A USP method for ceftizoxime was transferred to a superficially porous Agilent Poroshell 120 column for significant time and solvent savings.
- Publication Part Number: 5991-3717EN
- Created: 03 Dec 2013
- 90 KB
Publication Part Number | 5991-3717EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
The 1290 Infinity LC System and EclipsePlus 1.8 μm columns reduced solvent consumption and increased peak resolution, vs USP method, for curcuminoids extracted from turmeric
- Publication Part Number: 5991-3340EN
- Created: 31 Oct 2013
- 633 KB
Publication Part Number | 5991-3340EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Using the 1290 Infinity LC System coupled with the ZORBAX Eclipse Plus 3 × 100 mm, 1.8 μm column not only reduces solvent consumption, but allows for greater peak resolution.
- Publication Part Number: 5991-1971EN
- Created: 06 May 2013
- 1 MB
Publication Part Number | 5991-1971EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Emulation of Waters Alliance 2695 LC for analysis of aromatic acids using Agilent 1290 Infinity Binary LC with ISET.
- Publication Part Number: 5991-2019EN
- Created: 01 Apr 2013
- 1 MB
Publication Part Number | 5991-2019EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机The dissolution and assay analyses of norethindrone and mestranol are improved by using superficially porous Agilent Poroshell 120 columns
- Publication Part Number: 5991-1688EN
- Created: 07 Jan 2013
- 112 KB
Publication Part Number | 5991-1688EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机The dissolution and assay analyses of diphenhydramine and pseudoephedrine are improved by using superficially porous Agilent Poroshell 120 columns,
- Publication Part Number: 5991-1687EN
- Created: 07 Jan 2013
- 108 KB
Publication Part Number | 5991-1687EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
This Application Note describes the conversion of the USP normal-phase HPLC method for cholecalciferol assay to an SFC method using serially coupled columns.
- Publication Part Number: 5991-1456EN
- Created: 01 Dec 2012
- 751 KB
Publication Part Number | 5991-1456EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机The chromatographic purity and assay analyses of warfarin is improved by using superficially porous Agilent Poroshell 120 columns, as compared to the USP-suggested 5 µm column
- Publication Part Number: 5991-1686EN
- Created: 25 Nov 2012
- 162 KB
Publication Part Number | 5991-1686EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Application note for the sensitive determination of impurities in achiral pharmaceuticals by supercritical fluid chromatography
- Publication Part Number: 5990-6413EN
- Created: 01 Sep 2010
- 603 KB
Publication Part Number | 5990-6413EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for the analysis of amoxicillin and five impurities on the Agilent 1220 Infinity LC System
- Publication Part Number: 5990-6093EN
- Created: 01 July 2010
- 462 KB
Publication Part Number | 5990-6093EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|