Refine Results
- 必威体育赛事投注
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Compounds
-
Compounds
- Detection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
This shows the separation of four proteins by anion exchange chromatography using 4 different high salt-containing elution buffers (up to 2 M) for linear and step gradients.
- Publication Part Number: 5990-9614EN
- Created: 01 Aug 2013
- 658 KB
Publication Part Number | 5990-9614EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Ion exchange is a commonly used technique for the separation of complex protein mixtures.
- Publication Part Number: 5990-9931EN
- Created: 01 Aug 2013
- 2 MB
Publication Part Number | 5990-9931EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Ion exchange is a very useful technique to separate protein mixtures under mild conditions, most commonly by applying a shallow gradient of increasing salt concentration as el
- Publication Part Number: 5990-9629EN
- Created: 01 Aug 2013
- 1 MB
Publication Part Number | 5990-9629EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Columns containing weak cation-exchange stationary phases offer a degree of versability when used for separation of positively charged proteins.
- Publication Part Number: 5990-9628EN
- Created: 01 Aug 2013
- 1 MB
Publication Part Number | 5990-9628EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Column choice in SEC depends on column resolving range, identified by calibration with standards appropriate to analyte type, molecular weight range, and size in solution.
- Publication Part Number: 5991-2463EN
- Created: 14 May 2013
- 117 KB
Publication Part Number | 5991-2463EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Accurate mass intact protein analysis using 6550 iFunnel Q-TOF
- Publication Part Number: 5991-2116EN
- Created: 29 Mar 2013
- 613 KB
Publication Part Number | 5991-2116EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Methods are given for the use of Agilent Bio-SEC columns, with LS, UV and RI detection, for quantification or quality control of protein aggregates
- Publication Part Number: 5991-1400EN
- Created: 07 Jan 2013
- 284 KB
Publication Part Number | 5991-1400EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Rapid reversed-phase separations of intact and reduced monoclonal antibodies (mAbs) were optimized using Agilent ZORBAX RRHD 300SB-C3 columns.
- Publication Part Number: 5990-9667EN
- Created: 13 Feb 2012
- 364 KB
Publication Part Number | 5990-9667EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
JM
- Publication Part Number: 5990-9668EN
- Created: 07 Feb 2012
- 807 KB
Publication Part Number | 5990-9668EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|