Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Compounds
-
Compounds
- Detection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Application note for polyamide analysis on Agilent PL HFIPgel with Gel Permeation Chromatography
- Publication Part Number: 5990-7978EN
- Created: 01 Apr 2019
- 636 KB
Publication Part Number | 5990-7978EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机This manual covers the • G7821B Agilent 1260 Infinity II High Temperature Viscometer Detector
- Publication Part Number: G7821-90000
- Created: 23 July 2018
- 1 MB
A stepwise guide to developing a method for GPC or SEC with particular attention towards column choice, instrumentation, and troubleshooting.
- Publication Part Number: 5991-7272EN
- Created: 22 Aug 2016
- 560 KB
The advantages of multi-detection GPC to determine absolute molecular weight, size and shape of polymers are highlighted using the 1260 Infinity Multi-GPC/SEC System
- Publication Part Number: 5991-2891EN
- Created: 01 May 2016
- 1 MB
Flyer on fast GPC columns PlusPore range and PL Rapide
- Publication Part Number: 5991-2785EN
- Created: 18 Jan 2016
- 2 MB
Chinese (Simplified) (China) | Complete (PDF) |
---|
Polyethylene is a structurally simple material with a high commercial relevancy.
- Publication Part Number: 5991-5826EN
- Created: 30 Apr 2015
- 579 KB
Application note for the analysis of Polysaccharides by GPC Viscometry Using the 390-LC Multi Detector Suite (MDS)
- Publication Part Number: 5991-5841EN
- Created: 30 Apr 2015
- 773 KB
Application note for the analysis of Bromostyrene by GPC Triple Detection using the 390-LC Multi Detector Suite (MDS)
- Publication Part Number: 5991-5839EN
- Created: 30 Apr 2015
- 796 KB
Application note for the analysis of Polythiophenes via Conventional GPC
- Publication Part Number: 5991-5828EN
- Created: 30 Apr 2015
- 727 KB
必威体育登录手机Application note for branching analysis of polyethylenes by GPC and Agilent Cirrus Multi Detector Software
- Publication Part Number: 5990-8420EN
- Created: 30 Apr 2015
- 261 KB
Publication Part Number | 5990-8420EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Analysis of polymers by GPC for the energy and chemicals industry.Covers polyolefins, guar gums, engineering polymers, elastomers, and low molecular weight resins.
- Publication Part Number: 5991-2517EN
- Created: 30 Apr 2015
- 5 MB
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent PLgel columns can be used in a wide range of solvents, including polar organics, which facilitate the analysis of very polar samples such as polyvinylidene fluoride
- Publication Part Number: 5990-8328EN
- Created: 30 Apr 2015
- 117 KB
Publication Part Number | 5990-8328EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Application note for the analysis of Epoxy Resins by GPC Viscometry using the 390-LC Multi Detector Suite (MDS)
- Publication Part Number: 5991-5840EN
- Created: 30 Apr 2015
- 777 KB
Application note for the analysis of Modified Polyvinyl Alcohol by GPC Viscometry Using the 390-LC Multi Detector Suite (MDS)
- Publication Part Number: 5991-5838EN
- Created: 30 Apr 2015
- 789 KB
Application note for the analysis of Polystyrene Stars by GPC Viscometry with the 390-LC Multi Detector Suite (MDS)
- Publication Part Number: 5991-5837EN
- Created: 30 Apr 2015
- 1 MB
必威体育登录手机Application note for polystyrene stars on Agilent PLgel 5 μm MIXED-C using Gel Permeation Chromatography
- Publication Part Number: 5990-8487EN
- Created: 30 Apr 2015
- 639 KB
Publication Part Number | 5990-8487EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Phenol formaldehyde resins are made by the reaction of phenol and formaldehyde, through...
- Publication Part Number: 5990-8486EN
- Created: 30 Apr 2015
- 183 KB
Publication Part Number | 5990-8486EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机In this publication we demonstrate how the Agilent PL-GPC 220 High Temperature GPC System can be used to reliably discriminate between long chain branching polyethylene (LDPE)
- Publication Part Number: 5991-2781ENE
- Created: 16 Sep 2014
- 2 MB
Publication Part Number | 5991-2781EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Solutions for your analytical business
- Publication Part Number: 5991-4312ENE
- Created: 05 June 2014
- 2 MB
必威体育登录手机This Technical Overview describes a LC system with 3 detectors in a multi-user environment operated with Agilent MassHunter Walkup Software for LC/MS and LC systems.
- Publication Part Number: 5991-3198EN
- Created: 01 Oct 2013
- 949 KB