必威体育登录手机Technical information about the Agilent 1290 Infinity II Diode Array Detector FS (G7117A), Diode Array (G7117B), and 1260 Infinity II Diode Array Detector HS (G7117C).
- Publication Part Number: SD-29000132
- Created: 26 July 2024
- 5 MB
必威体育登录手机Thank you for purchasing an Agilent InfinityLab Online LC Solution.To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements.Correct site preparation is the key first step in...
- Publication Part Number: G1170A
- Created: 08 July 2024
- 2 MB
必威体育登录手机This manual contains technical reference information about the Agilent 1290 Infinity II High-Speed Pump (G7120A) and Agilent 1290 Infinity II Bio High-Speed Pump (G7132A).
- Publication Part Number: SD-29000230
- Created: 03 July 2024
- 28 MB
必威体育登录手机This document is for the Agilent InfinityLab Online LC Solution including Agilent InfinityLab 1260 Infinity II Online Sample Manager module (G3167A).
- Publication Part Number: D0006652
- Created: 03 July 2024
- 10 MB
必威体育登录手机This technical overview demonstrates how an Agilent 1260 Infinity II Online LC can be used in combination with the Flownamics SegFlow S3 and SampleMod modules for sampling from a bioreactor.
- Publication Part Number: 5994-7394EN
- Created: 06 May 2024
- 843 KB
This manual covers the InfinityLab LC Method Development Solutions, for example the 1260 Infinity II and 1290 Infinity II LC method development solutions.An LC method development solution consists of the corresponding hardware setup and the Method...
- Publication Part Number: SD-29000211
- Created: 11 Apr 2024
- 3 MB
必威体育登录手机This application note demonstrates the purification of a reaction mixture using an Agilent 1290 Infinity II Preparative LC System with RI detector in split flow.
- Publication Part Number: 5994-7318EN
- Created: 02 Apr 2024
- 318 KB
InfinityLab LC Series Site Preparation Checklist (Rev.C.04)
- Publication Part Number: G1328B
- Created: 15 Mar 2024
- 2 MB
必威体育登录手机Developing Fast Purification Methods for Natural Products Using an Agilent InfinityLab Poroshell 120 SB-C18 Preparative LC Column
- Publication Part Number: 5994-3518EN
- Created: 27 Feb 2024
- 605 KB
必威体育登录手机This application note describes the determination of mRNA capping using a PEEK-lined diol HILIC column installed on a 1290 Infinity II Bio LC System and hyphenated with an Agilent 6545 LC/Q-TOF.
- Publication Part Number: 5994-7118EN
- Created: 14 Feb 2024
- 1 MB
Seven sections in this eBook describe various powerful GPC/SEC applications and use cases in detail.
- Publication Part Number: 5994-5915EN
- Created: 13 Feb 2024
- 6 MB
Introduction to GPC/SEC detection including information on the most common GPC/SEC detectors including RI, LALS, RALS, MALS, viscometry, ESLD.
- Publication Part Number: 5994-5937EN
- Created: 13 Feb 2024
- 2 MB
This eBook covers the theory and background of gel permeation chromatography and size exclusion chromatography, GPC/SEC.
- Publication Part Number: 5994-5935EN
- Created: 13 Feb 2024
- 2 MB
This application note demonstrates the capability of monitoring the degradation of a monoclonal antibody (mAb) during production in a bioreactor.
- Publication Part Number: 5994-7091EN
- Created: 25 Jan 2024
- 731 KB
必威体育登录手机Whatever your GPC/SEC needs, Agilent has you covered.Discover our comprehensive range of integrated solutions and services for macromolecular analysis.
- Publication Part Number: 5994-6072EN
- Created: 01 Nov 2023
- 3 MB
必威体育赛事投注In this application note, a method was presented to quantify major components as well as degradation products of lithium-ion battery electrolytes, with particular attention to achieving separation of all analytes within 14 minutes.
- Publication Part Number: 5994-6859EN
- Created: 25 Oct 2023
- 755 KB
必威体育登录手机In this data sheet, the Agilent InfinityLab 2D-LC ProtA-SEC kit and service are described, with particular attention to the advantages the kit and corresponding optional service provides.
- Publication Part Number: 5994-3630EN
- Created: 20 Oct 2023
- 485 KB
WinGPC Software has automatic flow correction with an internal standard or flow marker to compensate for the negative effects of constantly fluctuating flow rates.
- Publication Part Number: 5994-5940EN
- Created: 14 Aug 2023
- 256 KB
必威体育登录手机The Agilent WinGPC ChromPilot sequence manager enables the execution of sawtooth gradients with the Agilent 1260 Infinity II GPC/SEC System.
- Publication Part Number: 5994-5946EN
- Created: 14 Aug 2023
- 296 KB
必威体育登录手机Agilent WinGPC Overlapping Injection function enables a sample to be injected before the previous sample has completely eluted, saving solvent and analysis time.
- Publication Part Number: 5994-5948EN