The three cradles of the DP instrument enable three separate electronic 16-well plates to be controlled and monitored in parallel or independently of one another.This flexible plate batch processing allows maximum productivity for multiple users.The instrument operates in a standard CO2 cell culture incubator and the control unit is housed outside the incubator.
Online data acquisition and offline data analysis are easy to perform using RTCA Software Pro, which also supports FDA 21 CFR Part 11 compliance.
- RTCA Analyzers
Product Details
- xCELLigence RTCA DP model can run up to three separate electronic 16-well plates (E-Plate 16 or CIM-Plate 16)
- Each well in the CIM-Plate 16 is an electronically integrated Boyden chamber, which enables the monitoring of cell invasion and migration in real-time (at second or minute intervals) without exogenous labels
- Non-invasive and label-free real-time impedance assay using E-plate 16 measures cell health, viability, or response to treatments with high sensitivity, accuracy, and reproducibility
- Obtain continuous data at high temporal resolution (from seconds to days)
- Easy workflow allows users to simply add cells to E-plates and begin kinetic measurements at physiological conditions, with minimal hands-on time
- Intuitive RTCA Software Pro allows for analysis of real-time data to generate diverse plot types and automatically calculate parameters such as % of cytolysis, IC50 or KT50
- RTCA Software Pro supports FDA 21 CFR Part 11 compliance to ensure electronic data integrity
Cellular Impedance Explained
The functional unit of a cellular impedance assay is a set of gold microelectrodes fused to the bottom surface of a microtiter plate well.When submersed in an electrically conductive solution (such as buffer or standard tissue culture medium), the application of an electric potential across these electrodes causes electrons to exit the negative terminal, pass through bulk solution, and then deposit onto the positive terminal to complete the circuit.
Learn More- Application Notes
-
xCELLigence Portfolio Cancer Immunotherapy Handbook
Recently updated Cancer Immunotherapy Handbook featuring the latest high impact xCELLigence publications and newly released supporting information.
- Application Notes
- English
- 10 Mar 2023
- 10.21 MB
A New Way to Monitor Virus-Mediated Cytopathogenicity
This application note describes the experimental setup for assessing vesicular stomatitis virus-mediated cytotoxicity of Vero E6 cells and HEK 293 cells using an xCELLigence instrument.
- Application Notes
- English
- 12 Feb 2021
- 358.59 KB
Label-Free Assay for NK Cell‑Mediated Cytolysis
In this application note, a series of experiments demonstrate how the xCELLigence RTCA system can be applied to quantitatively monitor NK cell‑mediated cytolysis without labeling the target cells.
- Application Notes
- English
- 12 Feb 2021
- 699.12 KB
Dynamic Monitoring of Receptor Tyrosine Kinase Activation in Living Cells
This application note highlights the development and utility of an alternative receptor tyrosine kinase assay that uses the impedance‑based xCELLigence system.
- Application Notes
- English
- 12 Feb 2021
- 1.58 MB
Dynamic Monitoring of G-Protein‑Coupled Receptor Activation in Living Cells
In this application note, a series of experiments demonstrates how the xCELLigence system may be used to monitor functional activation of GPCRs in living cells.
- Application Notes
- English
- 12 Feb 2021
- 1.07 MB
Dynamic Monitoring of Cell Adhesion and Spreading
In this application note, a series of experiments is described to demonstrate that the xCELLigence system is suitable for monitoring cell adhesion and spreading.
- Application Notes
- English
- 12 Feb 2021
- 1007.33 KB
Real-Time and Dynamic Monitoring of Cell Proliferation and Viability for Adherent Cells
This application note shows experiments that were conducted using xCELLigence instruments to assess cell proliferation and drug interaction with different cell lines.
- Application Notes
- English
- 19 Aug 2020
- 1.00 MB
Vaccine and Virology Applications
A collection of studies showing the benefits of xCELLigence RTCA assays over traditional assays.Antiviral drugs, virucides, neutralizing antibodies and other applications are examined.
- Application Notes
- English
- 02 Jul 2020
- 4.37 MB
Infectious Disease Applications
A compilation of studies demonstrating the application of xCELLigence RTCA to the analysis of bacterial toxins, biofilms, virus titer determination, and other areas of disease.
- Application Notes
- English
- 02 Jul 2020
- 4.93 MB
Studying Bacterial Biofilms Using Cellular Impedance
必威体育登录手机Describes the use of Agilent xCELLigence real-time cell analysis (RTCA) instruments for impedance monitoring.
- Application Notes
- English
- 02 Jul 2020
- 1.94 MB
- Brochures
- Data Sheets
- Flyers
- Instruction Sheets
-
Dell Ownership Transfer Process
Dell Ownership transferring process
- Instruction Sheets
- English
- 24 Aug 2020
- 417.41 KB
- Quick Reference Guides
- User Manuals
Didn't find what you need?Contact our dedicated Cell Analysis support teams.
Read reviews for RTCA DP - Cell Invasion & Migration
Explore customer reviews posted on SelectScience
必威体育登录手机Agilent Cell Analysis Publication Database
Search scientific publications by research area, cell type and more.