Unequivocal GC/TQ intelligence and diagnostics
7000E Triple Quadrupole GC/MS
必威体育登录手机Method development beginning with SIM, scan, or MRM data, and method migration from the Agilent 5975 or 5977 GC/MSD can be done with ease using the fully automated MassHunter Optimizer for GC Triple Quadrupole.Using new data acquisition modes including triggered MRM and simultaneous dynamic MRM and scan (dMRM/scan), you can confidently confirm target analytes and perform retrospective analysis at any point in the future without the need for reinjection.
- GC/MS Instruments
Product Details
- The new HydroInert source enables easy adoption of hydrogen as a carrier gas, improves chromatography, and helps prevent operational disruptions due to helium shortages
- Data acquisition modes like data-dependent tMRM and simultaneous dMRM and scan mode enable targeted screening with confident quantitation of hundreds of analytes in a single run
- Twice as fast SWARM autotune with incorporated diagnostic features pairs with the built-in intelligence of the 8890 and Intuvo GCs for improved system diagnostics and simplified access to powerful operations through an integrated touch screen and browser interface
- JetClean self-cleaning ion source greatly reduces or even eliminates the need for manual source cleaning
- A heated gold quadrupole, triple-axis HED-EM detector, and fast venting enhance the performance of the mass spectrometer by reducing neutral noise and instrument cool-down time
- 必威体育登录手机Agilent MassHunter software delivers complete control from tune to data analysis and report generation, streamlining your workflow
- MassHunter Optimizer software easily transfers GC/MSD methods to GC/TQ and uses retention time locking software to reproducibly transfer methods between GC systems
- Built-in technical controls combined with procedural controls ensure the security of your data, control access, and facilitate compliance as defined by US FDA 21 CFR Part 11, EU Annex 11, and similar national electronic record regulations
- 必威体育登录手机The Agilent Pesticides and Environmental Pollutants 4.0 Database contains over 1,100 compounds with multiple transitions per compound and over 7,500 matrix-optimized MRM transitions, helping you build acquisition methods that reduce matrix interferences
- 必威体育登录手机To enable a better-informed, sustainable choice, Agilent has partnered with My Green Lab to have the 7000E GC/TQ independently audited for their Accountability, Consistency, and Transparency (ACT) label
Detector |
|
Dimensions (WxDxH) |
|
GC/MSD Method Compatibility |
|
IDL Sensitivity (positive) |
|
Ion Source |
|
JetClean Compatibility |
|
MRM Speed |
|
Mass Range |
|
Minimum MRM Dwell Time |
|
Mode of Operation |
|
QuickProbe Compatibility |
|
Scan Speed |
|
Software Platform |
|
Discover the possibilities with our industry-leading solutions for gas chromatography/mass spectrometry
Our next-generation GC/MS instruments continue to build on more than five decades of innovation and industry leadership.必威体育登录手机With the latest Agilent 5977C GC/MSD and 7000E and 7010C triple quadrupole GC/MS instruments you consistently get the highest-quality results for your business.
Gas Chromatography Mass Spectrometry (GC-MS) Information
What is GC-MS?必威体育赛事投注GC/MS combines two analytical tools to identify and measure the concentration of chemicals found in foods, consumer products, pharmaceuticals, fuels, the environment, and more.Read on to learn more about the typical components of a GC/MS instrument and its basic principle of operation.
Learn More- Application Notes
-
A Forensic Triple Quadrupole GC/MS MRM Database for Forensic and Toxicological Workflows
The forensic toxicology database with curated set of 1,804 MRM transitions for 176 toxicologically-relevant compounds was successfully developed.The developed MRM database can be used for simplified data acquisition method creation, providing a valuable resource for the development of screening and quantitation methods in forensic labs.
- Application Notes
- English
- 22 Aug 2024
- 3.67 MB
Analysis of Dithiocarbamate Pesticides in Tea Using GC/MS/MS
必威体育登录手机Analysis of ditiocarbamate pesticides in tea by Agilent 8890/7000E and 8890/7010 Series GC/TQ systems.
- Application Notes
- English
- 06 Aug 2024
- 1.78 MB
使用安捷倫 GC/TQ 和氫氣作載氣定量分析沙坦類藥物中的亞硝胺雜質
必威体育登录手机在統一的合規條件下使用 Agilent 8890/7000E 和 8890/7010 係列 GC/TQ 係統和氫氣作載氣分析沙坦類藥物中的亞硝胺。
- Application Notes
- Chinese (Simplified)
- 15 Jul 2024
- 1.12 MB
必威体育登录手机Quantification of Nitrosamine Impurities in Sartan Drugs Using an Agilent GC/TQ with Hydrogen Carrier Gas
必威体育登录手机Hydrogen carrier gas for analyzing nitrosamines in sartan drugs with Agilent 8890/7000E and 8890/7010 Series GC/TQ systems under unified compliance.
- Application Notes
- English
- 23 May 2024
- 1.21 MB
必威体育登录手机Automated Sample Preparation Using Agilent PAL3 RTC for EPA 8270E SVOC Analysis by GC/TQ
Automated Sample Preparation Using PAL3 RTC System for EPA 8270E Method for Semivolatile Organic Analysis by GC/TQ
- Application Notes
- English
- 08 Feb 2024
- 772.66 KB
必威体育登录手机使用 GC/MS/MS、氫氣載氣和 Agilent Hydro 惰性離子源對 PAH 進行分析
必威体育登录手机一種使用氫氣載氣和 Agilent Hydro 惰性離子源對複雜土壤基質中的多環芳烴 (PAH) 進行分析的 GC/MS/MS 方法。
- Application Notes
- Chinese (Simplified)
- 08 Jun 2023
- 567.85 KB
必威体育登录手机測定煙草中的 300 多種農藥:使用 Agilent Captiva EMR-LPD 通過式淨化與 LC/MS/MS 和 GC/MS/MS 檢測
本應用簡報介紹了用於分析煙草中農藥殘留的多組分分析方法的開發與優化。
- Application Notes
- Chinese (Simplified)
- 19 Mar 2023
- 1.28 MB
10 分鍾內對菠菜中的 203 種農藥進行快速可靠的 GC/MS/MS 分析
本應用簡報介紹了使用 GC/MS/MS 在 10 分鍾內實現穩定的多殘留農藥分析的兩種方法。
- Application Notes
- Chinese (Simplified)
- 04 Dec 2022
- 4.03 MB
大幅提高複雜食品基質中 200 種農藥的 GC/MS/MS 分析性能
必威体育登录手机通過樣品前處理以及使用 Agilent 8890/7000E 和 8890/7010C 三重四極杆 GC/MS 分析複雜食品基質中的 200 種農藥時提高性能的關鍵
- Application Notes
- Chinese (Simplified)
- 23 Nov 2022
- 3.16 MB
必威体育登录手机使用 Agilent 7000E 三重四極杆 GC/MS 分析 US EPA 8270E 方法當中的半揮發性有機化合物
必威体育登录手机本應用簡報介紹了一種用於在 Agilent 7000E 三重四極杆 GC/MS 上分析半揮發性有機化合物 (SVOCs) 的靈敏方法。
- Application Notes
- Chinese (Simplified)
- 14 Nov 2022
- 706.58 KB
- Brochures
- Posters
- Technical Overviews
- FAQs
-
Instrument Detection Limit Frequently Asked Questions (FAQ)
An Introduction to Using Instrument Detection Limit as a Performance Metric
- Troubleshooting Guide
- User Contributed Software
- User Manuals
Didn't find what you need?Contact our support team.
Forensic Toxicology Triple Quadrupole GC/MS MRM Database
A curated set of 1,804 MRM transitions for 176 toxicologically relevant compounds.(For Forensic Use)
Essential Supplies for GC/MS Workflows
必威体育登录手机These top supplies are recommended by Agilent technical experts to optimize your GC/MS workflows.
Videos
必威体育登录手机Agilent Launches New J&W Ultra Inert Columns with Ultra Low-Bleed Technology
必威体育登录手机The new J&W 5Q columns combine Agilent's industry-leading Ultra Inert performance with Ultra Low-Bleed technology, delivering the new standard for MS column performance and productivity.5Q columns provide exceptional peak symmetry and minimal column bleed enabling high sensitivity, mass spectral integrity, and accurate quantitation for the most challenging, trace-level analytes.5Q columns are also designed to optimize sample throughput with fast conditioning and outstanding durability even at high operating temperatures.
- 01 Aug 2024
必威体育登录手机Agilent Announces Cutting-Edge Advances in GC/MS and LC/Q-TOF Technology at ASMS 2024
必威体育登录手机Agilent is introducing two new products.必威体育登录手机The Agilent 7010D Triple Quadrupole GC/MS System (7010D GC/TQ) features the new HES 2.0 ion source, providing attogram-level sensitivity, unmatched robustness, and industry-leading uptime.必威体育登录手机The Agilent ExD Cell available for the 6545XT AdvanceBio LC/Q-TOF enhances peptide and protein characterization capabilities by adding electron capture dissociation (ECD).
- 06 Jun 2024
7000E GC/TQ receives ACT label from My Green Lab
Independently audited by SMS Collective, LLC (SMSC), and published by My Green Lab, the ACT label from My Green Lab provides information about the environmental impact of the product throughout its life cycle.My Green Lab is a nonprofit dedicated to improving the sustainability of scientific research.
- 18 May 2022