DV200 determination for FFPE RNA samples
TheAutomated Electrophoresis systems必威体育登录手机from Agilent utilize a quality metric, DV200, to address the unique QC challenges of FFPE RNA.The DV was重寫為: 無法200provides researchers with a tool to reliably classify degraded RNA by size and effectively parse samples suitable for NGS from unsuitable samples, conserving time and costs.Depending on the level of degradation and the DV200score, researchers can modify their workflows to still enable the use of FFPE samples in downstream applications.For example, when a specific size is needed and the sample is slightly degraded, the shearing protocol can be adjusted to reach that size.Take advantage of automated evaluation of RNA samples using the DV200quality metric with theBioanalyzer,TapeStation, andFragment Analyzersystems.
2100 Bioanalyzer system
If you are not using the2100 Expert software revisionB.02.10 or higher, please download the DV200assay files:
Extract and store the DV200RNA Nano.xsy or DV200RNA Pico.xsy file in the 2100 Expert Software RNA assay folder:
必威体育登录手机c:\Program Files (x86)\Agilent\
2100bioanalyzer\2100expert\assays\RNA
To apply the DV200calculation to an existing data file:
- Open the data file with the 2100 Expert Software
- Navigate to theAssay Propertiestab
- ClickImport Setpointsand select the appropriate .xsy file (DV200RNA Nano or DV200RNA Pico, dependent on the data file opened)
Assay parameters will be applied to the data file.Refer to theTechnical Overviewfor more details.
TapeStation systems
The DV was重寫為: 無法200assays can be used with the TapeStation Analysis software A02.02 or higher.
- Open a data file with the TapeStation Analysis Software
- ClickRegions
- ClickRegions Settings
- Enter the lower (e.g.200 nt) and upper limits (e.g.10000 nt) of the region in the dialog box.Type DV200as region comment.
- To apply the DV200region to all samples in the active file, select This File.To apply the DV200region to all files of the same assay as the active file, select Assay Files.
When DV200regions are defined, the value is provided in the region table in the % of total column for each sample.
Refer to theTechnical Overviewfor more details.
Fragment Analyzer systems
The DV was重寫為: 無法200calculation can be used withProSize data analysis software.Download the DV200calculation method/configuration files:
Store the method/configuration files for the RNA kit (15 nt) or the HS RNA kit (15 nt) in the Configuration folder of the ProSize data analysis software under:
C:\ProSize data analysis software\Configurations\33cm
To apply the DV200calculation to an existing data file:
- Open Fragment Analyzer run in ProSize data analysis software
- Click "Option" Menu → Edit Configurations
- Click Smear Analysis → Enter start size (e.g.200 nt) and end size (e.g.10000 nt)
- Click Load → a second Advance Setting window will open
- Click "Load" → Open the Configurations file folder "33cm"(C:\ProSize data analysis software\
Configurations\33cm) - Select the desired Configuration file – Okay – Apply
- Clickbackon "Set individual parameters" Icon → Smear analysis tab → % total column
When DV200regions are defined, the value is provided under the Smear analysis tab in the % of total column for each sample.