Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column module and Agilent 490 Micro GC separates nitrous oxide in air in 75 seconds.
- Publication Part Number: A01240
- Created: 31 Oct 2011
- 391 KB
Publication Part Number | A01240 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column and Agilent 490 Micro GC analyzes nitrous oxide in air in 35 seconds.
- Publication Part Number: A01244
- Created: 31 Oct 2011
- 339 KB
Publication Part Number | A01244 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W PoraPLOT Q column analyzes eight decomposition gases from the explosive, 1,3,3-trinitroazetidine in 25 minutes.
- Publication Part Number: A01440
- Created: 31 Oct 2011
- 548 KB
Publication Part Number | A01440 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of inert gases in less than 150 seconds is achieved using an Agilent J&W PoraPLOT Q column and Agilent 490 Micro GC.
- Publication Part Number: A01633
- Created: 31 Oct 2011
- 407 KB
Publication Part Number | A01633 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|