Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column analyzes ethylene oxide spiked with light hydrocarbons, vinyl chloride, and acetaldehyde in 15 minutes.
- Publication Part Number: A0674
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00674 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT S column separates 21 light hydrocarbons in 14 minutes.
- Publication Part Number: A01455
- Created: 31 Oct 2011
- 669 KB
Publication Part Number | A01455 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 10 hydrocarbons in three minutes.
- Publication Part Number: A00581
- Created: 31 Oct 2011
- 536 KB
Publication Part Number | A00581 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 21 light hydrocarbons in 30 minutes.
- Publication Part Number: A01454
- Created: 31 Oct 2011
- 626 KB
Publication Part Number | A01454 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 12 halogenated and oxygenated hydrocarbons in 15 minutes.
- Publication Part Number: A00599
- Created: 31 Oct 2011
- 775 KB
Publication Part Number | A00599 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with Agilent J&W PoraPLOT U and PoraPLOT Q columns separate seven C1 to C3 hydrocarbons and chloromethane in 12 minutes.
- Publication Part Number: A00575
- Created: 31 Oct 2011
- 595 KB
Publication Part Number | A00575 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|