Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Injection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 21 light hydrocarbons in 30 minutes.
- Publication Part Number: A01454
- Created: 31 Oct 2011
- 626 KB
Publication Part Number | A01454 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates eight C1 to C3 hydrocarbons in ten minutes.
- Publication Part Number: A0451
- Created: 31 Oct 2011
- 657 KB
Publication Part Number | A00451 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT S column separates 21 light hydrocarbons in 14 minutes.
- Publication Part Number: A01455
- Created: 31 Oct 2011
- 669 KB
Publication Part Number | A01455 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight C1 to C3 hydrocarbons in 10 minutes.
- Publication Part Number: A0453
- Created: 31 Oct 2011
- 639 KB
Publication Part Number | A00453 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 14 C1 to C4 hydrocarbons in 12 minutes.
- Publication Part Number: A0440
- Created: 31 Oct 2011
- 704 KB
Publication Part Number | A00440 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT S column separates eight C1 to C3 hydrocarbons in 10 minutes.
- Publication Part Number: A0452
- Created: 31 Oct 2011
- 603 KB
Publication Part Number | A00452 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q-HT column separates nine C1 to C4 hydrocarbons in 12 minutes.
- Publication Part Number: A01299
- Created: 31 Oct 2011
- 690 KB
Publication Part Number | A01299 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 39 C1 to C4 nitriles and C1 to C5 hydrocarbons in 60 minutes.
- Publication Part Number: A00572
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00572 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机This application note shows the possibilities and limitations in fast analysis of saturated and unsaturated C1 to C3 hydrocarbons using an Agilent 490 Micro GC.
- Publication Part Number: 5990-9165EN
- Created: 04 Oct 2011
- 320 KB
Publication Part Number | 5990-9165EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|