Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Instrument
Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Bulk gaseous chemicals are not necessarily used close to their production site.
- Publication Part Number: 5991-1326EN
- Created: 23 Oct 2012
- 1 MB
Publication Part Number | 5991-1326EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 14 C1 to C4 hydrocarbons in 12 minutes.
- Publication Part Number: A0440
- Created: 31 Oct 2011
- 704 KB
Publication Part Number | A00440 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 15 C1 to C5 hydrocarbons and hydrogen sulfide in fuel gas in 16 minutes.
- Publication Part Number: A00574
- Created: 31 Oct 2011
- 665 KB
Publication Part Number | A00574 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with Agilent J&W PoraPLOT U and PoraPLOT Q columns separate seven C1 to C3 hydrocarbons and chloromethane in 12 minutes.
- Publication Part Number: A00575
- Created: 31 Oct 2011
- 595 KB
Publication Part Number | A00575 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with the Agilent 490 Micro GC and an Agilent J&W PoraPLOT Q column checks calibration bottles for the presence of residual solvent in 65 seconds.
- Publication Part Number: A01620
- Created: 31 Oct 2011
- 370 KB
Publication Part Number | A01620 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 21 light hydrocarbons in 30 minutes.
- Publication Part Number: A01454
- Created: 31 Oct 2011
- 626 KB
Publication Part Number | A01454 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates permanent gases in propylene in less than five minutes.
- Publication Part Number: A01272
- Created: 31 Oct 2011
- 880 KB
Publication Part Number | A01272 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column analyzes ethylene oxide spiked with light hydrocarbons, vinyl chloride, and acetaldehyde in 15 minutes.
- Publication Part Number: A0674
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00674 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q-HT column separates nine C1 to C4 hydrocarbons in 12 minutes.
- Publication Part Number: A01299
- Created: 31 Oct 2011
- 690 KB
Publication Part Number | A01299 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT S column separates 21 light hydrocarbons in 14 minutes.
- Publication Part Number: A01455
- Created: 31 Oct 2011
- 669 KB
Publication Part Number | A01455 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates four C1 to C4 hydrocarbons in two minutes at 30 oC and 1 minute at 60 oC.
- Publication Part Number: A0685
- Created: 31 Oct 2011
- 513 KB
Publication Part Number | A00685 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates four sulfur gases in six minutes.
- Publication Part Number: A0450
- Created: 31 Oct 2011
- 616 KB
Publication Part Number | A00450 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates gaseous impurities in ethylene in less than three minutes.
- Publication Part Number: A01273
- Created: 31 Oct 2011
- 296 KB
Publication Part Number | A01273 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates trace organic contaminants in ethylene and propylene bulk gas.
- Publication Part Number: A01557
- Created: 31 Oct 2011
- 427 KB
Publication Part Number | A01557 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates four C1 to C3 hydrocarbons in five minutes.
- Publication Part Number: A0290
- Created: 31 Oct 2011
- 423 KB
Publication Part Number | A00290 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 11 C1 to C6 hydrocarbons and solvents in less than five minutes.
- Publication Part Number: A0670
- Created: 31 Oct 2011
- 620 KB
Publication Part Number | A00670 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT S column separates eight C1 to C3 hydrocarbons in 10 minutes.
- Publication Part Number: A0452
- Created: 31 Oct 2011
- 603 KB
Publication Part Number | A00452 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with a high retention Agilent J&W PoraPLOT Q column separates C1 to C4 hydrocarbons, methanol and dimethyl ether at elevated temperatures in 14 minutes.
- Publication Part Number: A01507
- Created: 31 Oct 2011
- 538 KB
Publication Part Number | A01507 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 39 C1 to C4 nitriles and C1 to C5 hydrocarbons in 60 minutes.
- Publication Part Number: A00572
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00572 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|