Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Chemical Group
-
- Compounds
-
Compounds
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with Agilent J&W PoraPLOT U and PoraPLOT Q columns separate seven C1 to C3 hydrocarbons and chloromethane in 12 minutes.
- Publication Part Number: A00575
- Created: 31 Oct 2011
- 595 KB
Publication Part Number | A00575 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates four C1 to C4 hydrocarbons in two minutes at 30 oC and 1 minute at 60 oC.
- Publication Part Number: A0685
- Created: 31 Oct 2011
- 513 KB
Publication Part Number | A00685 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 11 C1 to C6 hydrocarbons and solvents in less than five minutes.
- Publication Part Number: A0670
- Created: 31 Oct 2011
- 620 KB
Publication Part Number | A00670 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates six C1 to C3 hydrocarbons and polar volatiles in five minutes.
- Publication Part Number: A0686
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00686 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates eight C1 to C3 hydrocarbons in ten minutes.
- Publication Part Number: A0451
- Created: 31 Oct 2011
- 657 KB
Publication Part Number | A00451 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column determines mg/L levels of water in pure propylene oxide in three minutes.
- Publication Part Number: A0758
- Created: 31 Oct 2011
- 356 KB
Publication Part Number | A00758 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|