Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
- Compounds
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Agilent 490 Micro GC with Agilent J&W PoraPLOT analyzes air near a garbage dump for methane, hydrogen sulfide and carbon dioxide in 70 s.
- Publication Part Number: A01618
- Created: 31 Oct 2011
- 364 KB
Publication Part Number | A01618 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with the Agilent 490 Micro GC and an Agilent J&W PoraPLOT Q column checks calibration bottles for the presence of residual solvent in 65 seconds.
- Publication Part Number: A01620
- Created: 31 Oct 2011
- 370 KB
Publication Part Number | A01620 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast GC analysis of inert gases in less than 150 seconds is achieved using an Agilent J&W PoraPLOT Q column and Agilent 490 Micro GC.
- Publication Part Number: A01633
- Created: 31 Oct 2011
- 407 KB
Publication Part Number | A01633 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column module and Agilent 490 Micro GC separates halogenated hydrocarbons in air in 250 seconds.
- Publication Part Number: A01340
- Created: 31 Oct 2011
- 573 KB
Publication Part Number | A01340 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column and Agilent 490 Micro GC analyzes nitrous oxide in air in 35 seconds.
- Publication Part Number: A01244
- Created: 31 Oct 2011
- 339 KB
Publication Part Number | A01244 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column module and Agilent 490 Micro GC separates cyanogen chloride in air in 55 seconds.
- Publication Part Number: A01632
- Created: 31 Oct 2011
- 350 KB
Publication Part Number | A01632 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column module and Agilent 490 Micro GC separates nitrous oxide in air in 75 seconds.
- Publication Part Number: A01240
- Created: 31 Oct 2011
- 391 KB
Publication Part Number | A01240 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
490-GC can be used for analyses of mine gas, especially carbon monoxide at low level which is essential for the safety of mine workers.
- Publication Part Number: SI-02235
- Created: 06 Sep 2012
- 642 KB
Publication Part Number | SI-02235 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|