Refine Results
- 必威体育赛事投注
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
- Injection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Bulk gaseous chemicals are not necessarily used close to their production site.
- Publication Part Number: 5991-1326EN
- Created: 23 Oct 2012
- 1 MB
Publication Part Number | 5991-1326EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 21 light hydrocarbons in 30 minutes.
- Publication Part Number: A01454
- Created: 31 Oct 2011
- 626 KB
Publication Part Number | A01454 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in 25 seconds.
- Publication Part Number: A02065
- Created: 31 Oct 2011
- 746 KB
Publication Part Number | A02065 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates gaseous impurities in ethylene in less than three minutes.
- Publication Part Number: A01273
- Created: 31 Oct 2011
- 296 KB
Publication Part Number | A01273 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q-HT column separates nine C1 to C4 hydrocarbons in 12 minutes.
- Publication Part Number: A01299
- Created: 31 Oct 2011
- 690 KB
Publication Part Number | A01299 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in a chlor-alkali cell in 60 seconds.
- Publication Part Number: A02064
- Created: 31 Oct 2011
- 729 KB
Publication Part Number | A02064 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates permanent gases in propylene in less than five minutes.
- Publication Part Number: A01272
- Created: 31 Oct 2011
- 880 KB
Publication Part Number | A01272 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates seven C3 to C8 ketones in 10 minutes.
- Publication Part Number: A0682
- Created: 31 Oct 2011
- 445 KB
Publication Part Number | A00682 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q-HT column separates 10 C3 to C6 hydrocarbons in 12 minutes.
- Publication Part Number: A01298
- Created: 31 Oct 2011
- 730 KB
Publication Part Number | A01298 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column analyzes ethylene oxide spiked with light hydrocarbons, vinyl chloride, and acetaldehyde in 15 minutes.
- Publication Part Number: A0674
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00674 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机This application note shows the possibilities and limitations in fast analysis of saturated and unsaturated C1 to C3 hydrocarbons using an Agilent 490 Micro GC.
- Publication Part Number: 5990-9165EN
- Created: 04 Oct 2011
- 320 KB
Publication Part Number | 5990-9165EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机This application note describes the use of the Agilent 490-PRO Micro GC for the analysis of liquefied ethane product.
- Publication Part Number: 5991-1817EN
- Created: 25 Jan 2013
- 527 KB
Publication Part Number | 5991-1817EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Korean (Korea) | Complete (PDF) |
---|
本應用簡報介紹了在燃料電池研究和開發及 β 測試中使用安捷倫微型氣相色譜儀分析氣體組分。
- Publication Part Number: 5991-3364CHCN
- Created: 01 Dec 2014
- 1 MB
Publication Part Number | 5991-3364EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
Sample Matrix |
|
必威体育登录手机Agilent J&W PLOT PT column installation and user guide.
- Created: 26 July 2013
- 1 MB
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column analyzes C3 oxygenated hydrocarbons in less than ten minutes.
- Publication Part Number: A01562
- Created: 31 Oct 2011
- 427 KB
Publication Part Number | A01562 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机propylene oxide impurities were analyzed with low method-detection limit, good resolution, sample recovery, and repeatability using Agilent J&W PoraBOND U.
- Publication Part Number: 5991-6074EN
- Created: 20 July 2015
- 77 KB
必威体育登录手机In this compendium, you'll find a compilation of Application Notes from past Agilent Information Pipeline eNewsetters, for the Energy and Chemical industry.
- Publication Part Number: Compendium
- Created: 04 Dec 2013
- 22 MB
必威体育登录手机使用Agilent 490 微型氣相色譜天然氣分析儀快速分析天然氣
- Publication Part Number: 5991-0275CHCN
- Created: 24 Sep 2014
- 3 MB