Refine Results
- 必威体育赛事投注
-
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Packaging
-
Packaging
- Solvent
-
Solvent
- Analyte
-
Analyte
- CAS Number
-
CAS Number
- Concentration
-
Concentration
- Format
-
Format
- Technique
-
Technique
- Unit Quantity
-
Unit Quantity
- Volume
-
Volume
- Analysis Platform
-
Product
- Language
-
Language
Compare
Intelliquant Multi-Element Standard 2.Contains Elements at 100 mg/L = Ce, Eu, Gd, Ho, La, Ni, S, Te
Component:
, 100 µg/mL;
Solvent:
5% Nitric acid
Packaging:
100 mL Bottle
Unit:
1 Each
Compare
Intelliquant Multi-Element Standard 3.Contains Elements at 100 mg/L = Co, Dy, Re, Sm, Th, V
Component:
, 100 µg/mL;
Solvent:
5% Nitric acid
Packaging:
100 mL Bottle
Unit:
1 Each
Compare
Intelliquant Multi-Element Standard 4.Contains Elements at 100 mg/L = B, Ba, Be, Bi, Ca, Cd, Cs, Cu, Ga, Hg, In, K, Li, Mg, Na, Se, Sr, Tl, Zn
Component:
, 100 µg/mL;
Solvent:
5% Nitric acid
Packaging:
100 mL Bottle
Unit:
1 Each
Compare
Intelliquant Multi-Element Standard 6.Contains Elements at 100 mg/L = Ge, Hf, Nb, Sb, Si, Sn, Ta, Ti, W, Zr
Component:
, 100 µg/mL;
Solvent:
5% Nitric acid with trace hydrofluoric acid
Packaging:
100 mL Bottle
Unit:
1 Each
Compare
Intelliquant Multi-Element Standard 7.Contains Elements at 100 mg/L = Au, Ir, Os, Pd, Pt, Rh, Ru
Component:
, 100 µg/mL;
Solvent:
15% Hydrochloric acid
Packaging:
100 mL Bottle
-
IntelliQuantin SemiQuant mode ICP-MS 7700
IntelliQuantin SemiQuant mode ICP-MS 7700
-
Hello all, What is the difference between theIntelliQuant/ noIntelliQuantmode in SemiQuant (QuickScan) ?When I activate this option, the LOQ are modified.InIntelliQuantmode, the LOQ is calculated according to TDS in sample ?Thanks in advance for yours answers, Have a good day,
-
How to UseIntelliQuantin ICP-MS MassHunter 5.1
How to UseIntelliQuantin ICP-MS MassHunter 5.1
-
This 4-minute video demonstrates theIntelliQuantfeature in MassHunter 5.1.
-
SemiQuant (intelliquant) analysis MassHunter ICP-MS 7700
SemiQuant (intelliquant) analysis MassHunter ICP-MS 7700
-
Hi, In Method -> SemiQuant -> SemiQuant Basic Parameters, there is a table with semiquant factor.How this factor is calculed?Thanks!
-
Intelliquanton the 7700 ICP-MS
Intelliquanton the 7700 ICP-MS
-
Good Day All, I have a need to do broad screening of a set of samples so I was hoping to useIntelliquantto get some estimate of the concentration.When I was playing with it today, I ran a known 5ppb multi-element standard and the results were all over the map.
Intelliquant 68 multi-element standard No.1 for ICP-OES, 5% HNO3, 100 μg/mL AL, AS, Ba, Be, Bi, B, Cd, Ca, Ce, Cs, Cr, Co, Cu, Dy, Er, Eu, Gd, Ga, Ho, In, Fe, La, Pb, Li, Lu, Mg, Mn, Nd, Ni, P, K, Pr, Re, Rb, Sm, Sc, Se, Na, Sr, Tb, Tl, Th, Tm,...
IntelliQuant multi-element standard No.2.Multi-element standard, for ICP_OES, 100 μg/mL Sb, Ge, Hf, Mo, Nb, Si, Ag, Ta, Sn, Ti W, Zr, in 5% HNO3, with trace HF, 500 mL
Intelliquant multi-element standard No.3.Multi-element Standard for ICP-OES 100 ug/mL Au,Ir,Os,Pd,Pt,Rh,Ru,Te in 10% HCL, 500 mL
Compare
Intelliquant Calibration Kit.Contains 8 Submixes = 5191-3933, 5191-3934,5191-3935,5191-3936,5191-3937,5191-3938,5191-3939, 5190-7001
Unit:
1 Kit
Compare
Intelliquant Multi-Element Standard 1.Contains Elements at 100 mg/L = Ag, As, Cr, Er, Lu, Mn, P, Pb, Rb, Sc, Tm, Y, Yb
Component:
, 100 µg/mL;
Solvent:
5% Nitric acid
Packaging:
100 mL Bottle
Compare
Intelliquant Multi-Element Standard 5.Contains Elements at 100 mg/L = Al, Fe, Mo, Nd, Pr, Tb, U
Component:
, 100 µg/mL;
Solvent:
5% Nitric acid
Packaging:
100 mL Bottle
Unit:
1 Each
An overview of QuickScan, IntelliQuant, and Star Rating
- Publication Part Number: 5994-7441EN
- Created: 27 May 2024
- 2 MB
Smarter and quicker semiquantitative ICP-OES analysis
- Publication Part Number: 5994-1518EN
- Created: 19 Apr 2022
- 397 KB
For greater sample insight and simplified method development
- Publication Part Number: 5994-1516EN
- Created: 19 Apr 2022
- 480 KB
快速的自動化半定量 ICP-MS 分析幫助您更深入了解樣品並提高結果可靠性
- Publication Part Number: 5994-2796ZHCN
- Created: 01 Dec 2020
- 432 KB
Fast, automated semiquantitative ICP-MS analysis provides greater sample insight and confidence in the results
- Publication Part Number: 5994-2796JAJP
- Created: 01 Dec 2020
- 940 KB
빠르고 자동화된 반정량 ICP-MS 분석으로 풍부한 시료 정보를 얻고 결과에 대한 신뢰도를 높이세요
- Publication Part Number: 5994-2796KO
- Created: 01 Dec 2020
- 363 KB
Smarter and quicker semiquantitative ICP-OES analysis
- Publication Part Number: 5994-1518RU
- Created: 16 Nov 2019
- 180 KB
For greater sample insight and simplified method development
- Publication Part Number: 5994-1516DEE
- Created: 16 Nov 2019
- 181 KB